Specifications
| Product Glance | Value |
| Model | ANTRACK |
| Version | V2 |
| Capacity | 4 units ANTMINER (Hydro) or 4 units ANTMINER (U2 Hydro) or 2 units ANTMINER (U3 Hydro) |
| Maximum load,kW | 24 |
| Detailed Characteristics | Value |
| Part 1: Mining Cabinet | |
| Hardware Configuration | |
| Size (Length*Width*Height), mm (without package) | 1200*600*1300 |
| Size (Length*Width*Height), mm (with package) | 1460*1330*780 |
| Net weight, kg (without package) | 130 |
| Gross weight, kg (with package) | 185 |
| Network connection mode | RJ45 Ethernet 10/100M |
| Power Supply | |
| Power supply AC Input voltage, Volt(1-1) | 380~415V AC |
| Power supply AC Input Frequency Range, Hz | 50~60 |
| Power supply AC Input current, Amp(1-2) | 63 |
| Water pump | |
| Rated power, W | 450 |
| Noise, dBA@1m | 60 |
| Lift, m | 19 |
| Size (Length*Width* Height), mm | 360*210*268 |
| Plate heat exchanger | |
| Maximum heat exchange power, kW | 30 |
| Size (Length*Width* Height), mm | 305*106*64 |
| Diameter of water pipe connector, mm | DN20 |
| Part 2: External Cooler(1-3) | |
| Hardware Configuration | |
| Size (Length*Width*Height), mm (without package) | 1160*1035*1570 |
| Size (Length*Width*Height), mm (with package) | 1310*1185*1770 |
| Net weight, kg (without package) | 380 |
| Gross weight, kg (with package) | 432 |
| Power supply | |
| Power supply AC input voltage, Volt(1-1) | 380~415V AC |
| Power supply AC input frequency range, Hz | 50~60 |
| Maximum power supply AC input current, Amp(1-2) | 63 |
| Heat pump | |
| Heating Capacity (typical), kW | 32 |
| Compressor Input (typical), kW | 8 |
| EER (typical) | 3 |
| Sound Level, Db(A) | 77 |
| Refrigerant | R134a |
| Heating water outlet temperature, °C | 80 |
| Fan | |
| Rated power, W | 1900 |
| Noise, dBA@1m | 74 |
| Size (Length*Height*Thickness), mm | 1010*1010*369 |
| Water pump | |
| Rated power, W | 370 |
| Noise, dBA@1m | 74 |
| Size (Length*Width* Height), mm | 328*205*461 |
| Environment Requirements | |
| Ambient temperature, °C | -20~40 |
| Water flow, L/min | 32.0~40.0 (Cabinet side) |
| Water pressure, bar | ≤3.5 |
| Working fluid(1-4) | Antifreeze (10%) |
| Installation distance, m(1-5) | 50 |
| Liquid PH | 7.8~8.5 |
| Storage temperature, °C | -20~70 |
| Operation humidity(non-condensing), RH | 10~90% |
Notes:
(1-1) Caution: Wrong input voltage may probably cause miner damaged.
(1-2) Three-phase AC input.
(1-3) The External cooler (heat pump) should be placed outdoors in a well-ventilated environment.
(1-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.
(1-5) The distance between mining cabinet and external cooler.
Specification Details For U3S19 XP+H.
| Product Glance | |
| Model | U3S19XP+H |
| Sub | 504T | 532T | 558T | 586T |
| Version | 10 |
| Crypto algorithm/coins | SHA256 | BTC/BCH/BSV |
| Typical hashrate, TH/s(1-1) | 504T |532T |558T |586T |
| Power on wall @35°C(1-2), Watt(1-1) | 9576 |10108 |10602 |10900 |
| Power efficiency on wall @35°C(1-2), J/TH(1-1) | 19 |
| Detailed Characteristics | |
| Power Supply | |
| Phase | 3 |
| Input voltage, Volt(2-1) | 380~415 |
| Input Frequency Range, Hz | 50~60 |
| Input max current, Amp | 24 |
| Power Port | LP34 |
| Hardware Configuration | |
| Networking connection mode | RJ45 Ethernet 10/100M |
| Server Size (Length*Width*Height, w/o package), mm | 790*440*130 |
| Server Size (Length*Width*Height, with package), mm | 997*637*252 |
| Net weight, kg | 37 |
| Gross weight, kg | 41 |
| Environment Requirements | |
| Inlet coolant temperature,°C | 20~50 |
| Coolant flow, L/min | 16.0~20.0 |
| Coolant pressure, bar | ≤3.5 |
| Working coolant(2-2) | Antifreeze/ Pure water/Deionized water |
| Coolant pH value | Antifreeze: 7.0~9.0 Prue water: 6.5~7.5 Deionized water:8.5~9.5 |
| Diameter of coolant pipe connector, mm | OD14 |
| Storage temperature,°C | -20~70 |
| Operation humidity(non-condensing) , RH | 10~90% |
NOTE:
(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%.
(1-2) Inlet coolant temperature.
(2-1) Caution: Wrong input voltage may cause server damaged.
(2-2) For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Hydro Cooling Container & Dry-Wet Tower Product Manual“, Chapter 9, Article 3, Point 6, “Maintenance of Coolant“!














Reviews